Measures the stereo calibration and the camera-to-motion-signal time offset from the recording itself.
| Reference | Category | Runs once per | Reads | Writes | Resources |
|---|---|---|---|---|---|
embodiflow/sensor-calibrate@2 | Enrich | recording | recording | features | 4 vCPU, 8Gi memory |
Parameters
| Parameter | Type | Default | Range or choices | What it does |
|---|---|---|---|---|
stereo_sample_hz Stereo samples per second | number | 1 | 0.1 to 15 | |
max_stereo_pairs Most stereo frame pairs | integer | 300 | 10 to 600 | |
max_stereo_skew_ms Largest left/right skew (ms) | number | 3 | 0.5 to 16.7 | |
time_offset_search_ms Time offset search window (ms) | number | 100 | 20 to 500 | |
time_offset_max_seconds Seconds used for the time offset | number | 240 | 20 to 3600 | |
workers Worker threads | integer | 6 | 1 to 32 | |
cam_imu_rotation Camera to IMU rotation source | string | "measured" | measured, device |
Set them on the step in the workflow editor, or in the workflow YAML under the step's with:. See Build a workflow.
Checks
Each check reports pass, warn, fail, error, not evaluated or not applicable for every recording or episode it judges. Only pass is green. Whether a fail stops processing: see Stop bad recordings.
| Check | Title | What it means |
|---|---|---|
stereo_rectified_dy | Rectified stereo rows line up | Median vertical offset of matched points after rectification, below 1 px. |
factory_calibration | Factory stereo calibration is close | The refined rotation is within 3 degrees of the device's own calibration. |
factory_intrinsics | Factory right camera intrinsics fit | The right camera's principal point is within 20 px and its focal length within 1 % of the device's, or refining them did not help. |
time_offset | Camera and IMU clocks agree | Residual camera to IMU time offset after the profile latency, warning above 10 ms. |
Features it writes
| Feature | Type | Per | Unit |
|---|---|---|---|
calibration.stereo | calibration.stereo | recording | |
calibration.cam_imu | calibration.cam_imu | recording |
Versions
A workflow step names the major version: embodiflow/sensor-calibrate@2; a run freezes the highest released 1.x version when it starts and records it. The console's algorithm page lists every released version under Versions.