EmbodiFlowDocs
Open console
Get startedAlgorithms and workflowsDataTrainingReference
  • Reference

Tools

  • CLI reference
  • Python SDK

Algorithms and workflows

  • Algorithm interface and manifest
    • Standardize
    • Check
    • Transform
    • Enrich
    • Segment
    • Filter
    • Export
  • Built-in algorithms
    • Anonymize
    • Body pose (SMPL-H)
    • Head pose (visual-inertial)
    • Standardize MCAP
    • Standardize video
    • Ego 3D visualization
    • Episode success
    • Filter episodes
    • Hand pose (MANO)
    • Hand pose
    • LeRobot v3 export
    • Import LeRobot
    • Video preview
    • Poster frames
    • Propose episodes
    • Raw-file metrics
    • Recording episodes
    • Sensor calibration
    • Split episodes
    • Stereo depth
    • Visual metrics

API

  • REST API
  • All endpoints
  • Projects
    • Recordings
      • Upload
        • Episodes and versions
          • Health and quality
            • Workflows
              • Algorithms
                • Export and training
                  • Billing and usage
                    • Team and governance
                      • Account and notifications
                        • Webhook endpoints
                          • Authentication
                          • API keys
                          • Personal access tokens
                          • Browser sessions
                          • Webhooks and signatures

                          Help

                          • Troubleshooting
                          • Changelog

                          © 2026 EmbodiFlow

                          Open consolellms.txtOpenAPI JSON
                          1. Reference
                          2. Algorithms and workflows
                          3. Built-in algorithms
                          4. Sensor calibration

                          Sensor calibration

                          Measures the stereo calibration and the camera-to-motion-signal time offset from the recording itself.

                          Measures the stereo calibration and the camera-to-motion-signal time offset from the recording itself.

                          From the manifest: Measure the stereo rotation, the right camera's principal point and focal length, and the camera to IMU time offset of each recording from its own images and IMU.
                          ReferenceCategoryRuns once perReadsWritesResources
                          embodiflow/sensor-calibrate@2Enrichrecordingrecordingfeatures4 vCPU, 8Gi memory

                          Parameters

                          ParameterTypeDefaultRange or choicesWhat it does
                          stereo_sample_hz Stereo samples per secondnumber10.1 to 15
                          max_stereo_pairs Most stereo frame pairsinteger30010 to 600
                          max_stereo_skew_ms Largest left/right skew (ms)number30.5 to 16.7
                          time_offset_search_ms Time offset search window (ms)number10020 to 500
                          time_offset_max_seconds Seconds used for the time offsetnumber24020 to 3600
                          workers Worker threadsinteger61 to 32
                          cam_imu_rotation Camera to IMU rotation sourcestring"measured"measured, device

                          Set them on the step in the workflow editor, or in the workflow YAML under the step's with:. See Build a workflow.

                          Checks

                          Each check reports pass, warn, fail, error, not evaluated or not applicable for every recording or episode it judges. Only pass is green. Whether a fail stops processing: see Stop bad recordings.

                          CheckTitleWhat it means
                          stereo_rectified_dyRectified stereo rows line upMedian vertical offset of matched points after rectification, below 1 px.
                          factory_calibrationFactory stereo calibration is closeThe refined rotation is within 3 degrees of the device's own calibration.
                          factory_intrinsicsFactory right camera intrinsics fitThe right camera's principal point is within 20 px and its focal length within 1 % of the device's, or refining them did not help.
                          time_offsetCamera and IMU clocks agreeResidual camera to IMU time offset after the profile latency, warning above 10 ms.

                          Features it writes

                          FeatureTypePerUnit
                          calibration.stereocalibration.stereorecording
                          calibration.cam_imucalibration.cam_imurecording

                          Versions

                          A workflow step names the major version: embodiflow/sensor-calibrate@2; a run freezes the highest released 1.x version when it starts and records it. The console's algorithm page lists every released version under Versions.

                          Previous

                          Recording episodes

                          Next

                          Split episodes